go to text
Holo / Or Ltd. (Israel): Holoror: Holoor (Israel):Diffractive Optical Element (DOE) Manufacturer
Please contact the import agency Taihei Boeki for details.

ELONGATED Focus DOE Holo/Or (Holoor)

Holo/Or's ELONGATED Focus series is a Diffractive Optical Element (DOE) that produces a Bessel beam and manipulates the propagation axis of the laser beam. A new solution with enhanced depth of focus (DOF) and high lateral resolution (small beam waist).
Traditional optics (spherical lenses, mirrors, etc.) cannot achieve these two at the same time. High numerical aperture (NA) is required for high lateral resolution, but low NA is required for long depth of focus.
Holo/Or has succeeded in achieving a focal point (cylinder) with sharp edges and an extended depth of focus while keeping the laser spot size very small.

principle

Diffractive stretch focus, which can be explained by Holo/Or's multifocal lens. This diffractive multifocal lens is an optical element commonly used in laser applications and eye surgery (intraocular lenses are usually multifocal lenses).
A multifocal lens divides the incident beam into several spots along the focal length (Z axis) and focuses them at each location. Diffractive stretch focus works in a similar way, but produces a continuous function rather than discretely dividing into a specific number of focal points. Therefore, the incident beam can be continuously focused along the optical axis to generate an elongated focal effect (long focus depth).
Note that a small amount of energy will be in focus and the rest of the energy will be out of focus in each plane along the optical axis. So unfocused energies appear as low energy rings and lobs.

Theory

For a normal Gaussian laser beam, the depth of focus is defined by:
Δ: Decrease in energy density
ZRx: Rayleigh length
M²: Beam quality
d: Beam diameter (1 / e²)
F: Focal length (condensing lens)
λ: Wavelength
When using Holo/Or's stretched focus, the length of the focal area is determined by the angle of the element, the focal length of the external lens, and the beam diameter. Theoretically, it is possible to design for a very long depth of focus, but the price is that the energy density of the central spot is reduced.
A small focal extension is sufficient to improve the process without making major changes to the optical setup, which can be achieved without the need for laser replacement or focal length changes.

Change the depth of focus

Depth of focus can be scaled to different condenser lenses than the following formula.
Δ: Depth of focus    Δ0: Initial depth of focus
λ: Operating wavelength λ0: Initial wavelength
fr: Focal length fr0: Initial focal length
Another way to change the depth of focus is to change the size of the incident beam.
w0: Initial beam size

If the change in depth of focus is small, we recommend using a binary type elongated focal element. The depth of focus of these elements is about 1.5 times that of the system without the elements.

  • Increased focal length = Increased depth of focus
  • Increased beam size = Decreased depth of focus

Positive vs negative

The following figure shows the difference in the depth of focus (DOF) position between "negative long focus" and "positive long focus". The depth of focus of the negative stretch focus is after the focal plane of the lens, and the positive type is before the focal plane of the lens.
No stretch focus
Negative stretch focus
Positive stretch focus
Example 1) Stretched focus vs Gaussian beam
Example 2) Comparison by difference in incident beam size

Product List

 
10600nm 1030nm 532nm 266nm 
1550nm 980nm 405nm 193nm 
1064nm 635nm 355nm  

Various data sheets, drawings, BB files, etc. are available separately
Please contact us for details
Hydrogen-related products
Click here for the special page
Optical Equipment Online Shop
Click here for Lens-Do
Back to TOP